Luminaire selection
Luminaire selection chart
A B C D E F G H I K L M N O P R S T U V W
Application | Protection rating | Regulations | Recommended product groups | Remarks |
|
|
|
|
|
Agricultural facilities | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. In case of animal husbandry consider ammonia resistance (see chapter “Chemical safety” ). |
|
Air halls for storage | IP 20 | Diffuser luminaires Nextrema⋅⋅⋅, Duroxo⋅⋅⋅ | Protection rating dependent on stored goods, in case dust occurs: IP50. In case of VDUs avoid reflex formation. |
|
Archive rooms | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Arimo Slim D CDP⋅⋅⋅ | In case dust occurs: IP50. In case of VDU workspaces consider luminance limitation |
|
Automobile washing rooms | IP54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅ | Direct contact of the luminaire with cleaning agents can lead to embrittlement of diffuser fasteners etc. (see chapter “Chemical safety” ). Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature. |
|
Automobile workshops | IP20 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ , Continuous-line luminaires: E-Line⋅⋅⋅, C-Line⋅⋅⋅, Coriflex⋅⋅⋅ | In case of cleaning with jet water: IPx5, with pressure washers: IPx9. Stand-by lighting must be planned for in case of workspaces with particular hazards (also see Chapter “Emergency lighting”). In case of contact with fats and oils, luminaire covers made of PMMA are recommended. |
|
|
|
|
|
|
Badminton halls | IP20 | Diffuser luminaires: Actison⋅⋅⋅ with PMMA cover | Special luminaire placement, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”) |
|
Bakeries | IP40 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | In wet areas IP44, in case of cleaning with splash water IPx4, with jet water: IPx5, with pressure washers: IPx9. Where applicable, in rooms with flour silos IP54. Consider ambient temperature, plan safety lighting for workspaces with particular hazards (also see Chapter “Emergency lighting”). |
|
Banks, teller windows/booking halls | IP20 | Diffuser luminaires: Arimo Slim CDP⋅⋅⋅, Belviso Active⋅⋅⋅, louvre luminaires: Arimo Slim MRX⋅⋅⋅, work zone luminaires, if applicable: Belviso S⋅⋅⋅, Offset S⋅⋅⋅, Lateralo⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅, Parelia⋅⋅⋅, Bicult⋅⋅⋅ | In case of VDU workspaces consider luminance limitation. Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Basket weaving plant: bast, reeds, reed, straw | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Bath and laundry facilities | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Bathrooms and shower rooms, general | IP20 | Diffuser luminaires: Acuro⋅⋅⋅, Solvan Flow C⋅⋅⋅, Polaron IQ⋅⋅⋅, Onplana⋅⋅⋅, Inplana⋅⋅⋅, Arimo Sky⋅⋅⋅, Arimo Slim CDP⋅⋅⋅ | Outside Zone 0, 1 und 2. |
|
Bathrooms and shower rooms, zone 0 | IPx7 |
| Cleaning with pressure washers: IPx9 |
|
Bathrooms and shower rooms, zone 1 | IPx4 | LED luminaires, protection class III | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Bathrooms and shower rooms, zone 2 | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Beer and wine cellars | IPx1 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | In case of cleaning with splash water IPx4, with jet water: IPx5, with pressure washers: IPx9. |
|
Blackboards | IP 20 | Louvre and diffuser luminaires: 504⋅⋅⋅ | Utilise luminaires with asymmetrical or narrow-angle light distribution, consider glare limitation. |
|
Boiler houses | IPx1 | Weather-proof luminaires, Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature. |
|
Business premises (salesrooms) | IP20 | Downlights: Inplana⋅⋅⋅, Onplana⋅⋅⋅, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Diffuser and louvre luminaires: Arimo Slim MRX ⋅⋅⋅, Arimo Sky⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Accent luminaires | In case dust occurs: IP50. In case of VDU workspaces consider luminance limitation, light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
|
|
|
|
|
CAD rooms | IP 20 | work zone luminaires: Bicult⋅⋅⋅, Belviso S⋅⋅⋅, Offset S⋅⋅⋅, Lateralo⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅, Parelia⋅⋅⋅ | Consider luminance limitation, brightness control recommended. |
|
Canteen kitchens | IPx4 | Weather-proof luminaires: Fidesca BS⋅⋅⋅, Nextrema⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature, in case of cleaning with aggressive cleaning agents, consider chemical resistance (see Chapter “Chemical safety”). |
|
Cellar, heated and ventilated | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | In case dust occurs IP50. |
|
Cellar, unheated and unventilated | Px1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Humid room. |
|
Cellar, wine and beer | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | In case of cleaning with splash water IPx4, with jet water: IPx5, with pressure washers: IPx9. |
|
Cinema halls | IP20 | Wall-mounted luminaires: Polaron IQ⋅⋅⋅, Downlights: Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅ , Accent luminaires | Light accents increase the perceived value of the lighting. Emergency lighting of escape routes for 3 hour length of operation, where applicable anti-panic lighting (also see Chapter “Emergency lighting”) |
|
Classrooms, blackboards | IP 20 | Utilise luminaires with asymmetrical or narrow-angle light distribution, consider glare limitation. |
||
Classrooms, general | IP 20 | 3331⋅⋅⋅, Solvan Flow C⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅; Arimo Slim CDP ⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅ | Consider glare limitation. |
|
Classrooms, handicrafts | IP 20 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard, when indicated. |
|
Classrooms, music | IP 20 | Diffuser luminaires: 3331⋅⋅⋅, Deca⋅⋅⋅, Polaron IQ⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅ | Take noise level into consideration, luminaire louvres and loose components as well as ceiling components can be excited into resonance vibrations. |
|
Cold-storage rooms, frozen storage rooms | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅ | Particularly in case of short time operation LED-luminaires are recommended. Consider temperature specifications from the instruction sheet. In case of very deep temperatures use specified luminaires. |
|
Combing and carding, textiles | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Concert halls, music schools | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Polaron IQ⋅⋅⋅, 74R⋅⋅⋅, 74Q⋅⋅⋅ | Take noise level into consideration, luminaire louvres and loose components as well as ceiling components can be excited into resonance vibrations, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Cork processing | IP50 | Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Corridors, staircases | IP20 | Downlights, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Diffuser luminaires: 3331⋅⋅⋅, Wall-mounted luminaires: 74R⋅⋅⋅, 74Q⋅⋅⋅, 748⋅⋅⋅, Polaron IQ⋅⋅⋅ | In case of increased occurrence of dust IP50 in the hand area, utilise diffuser luminaires and/or lamp with protective tubing. Avoid glare and irritations at stairs through correct lighting, LED luminaires preferred (in particular in case of automatic switching systems with short operating duration) |
|
|
|
|
|
|
Dairies | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Data archive and data acquisition rooms | IP20 | Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Arimo Slim⋅⋅⋅, Fidesca SD⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅, work zone luminaires, if applicable: Parelia⋅⋅⋅ | In case dust occurs IP50, VDU-compliant illumination required. |
|
Data centres (see Data acquisition) | IP20 | Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Arimo⋅⋅⋅, Fidesca SD⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅, work zone luminaires, if applicable: Parelia⋅⋅⋅ | In case dust occurs IP50, VDU-compliant illumination required. |
|
Drying rooms | IP50 | Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
|
|
|
|
|
EEG, ECG, EMG rooms | IP20 | Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅, Arimo Sky⋅⋅⋅ | Illumination level and light colour differing dependent on the type of examination, in case of VDU workspaces consider luminance limitation. Where applicable, dimmable luminaires. |
|
Event rooms | IP20 | Wall-mounted luminaires: 3331⋅⋅⋅, Polaron IQ⋅⋅⋅, 74R⋅⋅⋅, 74Q⋅⋅⋅, Downlights: Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅ , Accent luminaires Scenatic Point 905⋅⋅⋅ | In case of VDU workspaces consider luminance limitation. Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics. Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Event tents, tents | IP 54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Hallenspiegelleuchten: Mirona Fit⋅⋅⋅ | Lamps that are - in the traffic area of the audience - located at a height of 2 m above the floor must be equipped with a protection against breaking due to mechanical stress. |
|
Exhibition rooms | IP20 | Based on photometric requirements |
Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”) |
|
Exterior areas, exposed to rain | IPx3 | Outdoor luminaires, Weather-proof luminaires: (restricted, in accordance with the product documentation): Duroxo⋅⋅⋅, Nextrema⋅⋅⋅ |
|
|
Exterior areas, ramps (covered) | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Downlights: Inperla Ligra Plus (with cover), Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Limit glare while loading. |
|
|
|
|
|
|
Factory farming | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅ |
In case dust occurs IP54, consider ammonia resistance (see chapter “Chemical safety” ). |
|
Feed kitchens (agricultural facilities) | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washer: IPx9, consider ambient temperature. |
|
Feed processing (agricultural facilities) | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. |
|
Fertilizer shed | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | In case dust occurs IP54, where applicable, premises posing a fire hazard. Where applicable, adhere to explosion protection. |
|
Film screening rooms (audience) | IP20 | Wall-mounted luminaires, Downlights, Accent luminaires | Accent lighting increases the perceived value of the lighting. Emergency lighting of escape routes for 3 hour length of operation, where applicable anti-panic lighting (also see Chapter “Emergency lighting”). |
|
Food processing, drying | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. Protection against mechanical damage (breakage of glass) in the processing area is required. |
|
Food processing, fermenting, pressing/squeezing | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, protection against mechanical damage (breakage of glass) in the processing area is required. |
|
Food processing, general | IP20 | Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, take hygiene regulations into consideration, protection against mechanical damage (breakage of glass) in the processing area is required. |
|
Food processing, slaughtering | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, take hygiene regulations into consideration, protection against mechanical damage (breakage of glass) in the processing area is required. |
|
Freight forwarding operations | IP20 | Continuous-line luminaires: E-Line⋅⋅⋅ | In case dust occurs IP50 |
|
|
|
|
|
|
Galvanic facilities | IPx4 | Weather-proof luminaires, High bay luminaires: on request | Cleaning with jet water: IPx5, with pressure washer: IPx9, plan safety lighting for workspaces with particular hazards (also see chapter “Emergency lighting”). |
|
Garages, car parks, underground car parks | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Gas stations, roofed over | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Mirona Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Gateways | IPx3 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Limit glare while loading |
|
Granaries | IP54 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. Where applicable, adhere to explosion protection. |
|
Greenhouses | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, High bay luminaires: Mirona Fit⋅⋅⋅ | In case dust occursIP54, cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Gymnasium and sports halls | IP20 | Ball-proof luminaires: Actison⋅⋅⋅ |
Ball-impact-resistant luminaires (see Chapter “Mechanical safety”). In case of radiant ceiling heating system, further inquiry required. |
|
|
|
|
|
|
Hosiery factory | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ |
|
|
Hotel rooms | IP20 | Downlights: Inplana⋅⋅⋅, Onplana⋅⋅⋅, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅) , Wall-mounted luminaires (z. B. Polaron IQ⋅⋅⋅, Accent luminaires | Comfortable lighting very important, utilise accent lighting, brightness control recommended. |
|
|
|
|
|
|
Industrial halls | IP20 | Continuous-line luminaires: E-Line⋅⋅⋅, C-Line⋅⋅⋅, Coriflex⋅⋅⋅, High bay luminaires: Mirona Fit⋅⋅⋅ |
In case dust occurs: IP50. In the hand area diffuser luminaires and/or lamps with protective tubing, zonal lighting in case of high light levels through suspended luminaires, in case of special environmental conditions (temperature, humidity, aggressive media, etc.) utilise corresponding luminaires. |
|
|
|
|
|
|
Kitchens, commercial kitchens | IPx4 | Weather-proof luminaires: Fidesca BS⋅⋅⋅, Nextrema⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature, in case of cleaning with aggressive cleaning agents, consider chemical resistance (see Chapter “Chemical safety” ). |
|
Kitchens, feed kitchens (agricultural facilities) | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature. |
|
Kitchens, sculleries | IPx4 | Weather-proof luminaires: Fidesca BS⋅⋅⋅, Nextrema⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature, in case of cleaning with aggressive cleaning agents, consider chemical resistance (see Chapter “Chemical safety” ). |
|
|
|
|
|
|
Laboratories | IP 20 |
In case dust occurs: IP50. In the hand area diffuser luminaires and/or lamps with protective tubing, if applicable, take chemical resistance into consideration (see Chapter “Chemical safety” ), in case of VDU workspaces consider luminance limitation. |
||
Laundry rooms/facilities | IPx1 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Leather processing | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: hrefhttp://www.trilux.com/TOC/NEXTREMAG3Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Livestock breeding, ancillary rooms | IP44 | Weather-proof luminaires: hrefhttp://www.trilux.com/TOC/DUROXODuroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. consider ammonia resistance (see chapter “Chemical safety” ). |
|
Livestock breeding, intense | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅ | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. Consider ammonia resistance (see chapter “Chemical safety” ). |
|
|
|
|
|
|
Meat and fish processing processing plants | IPx5 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, in case of cleaning with aggressive cleaning agents, consider chemical resistance (see Chapter “Chemical safety” ). Plan safety lighting for workspaces with particular hazards. |
|
Milk chambers (agriculture) | IP44 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Milking parlours | IP44 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Mobile constructions, event tents, event booths | IP 54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, High bay luminaires: Mirona Fit⋅⋅⋅ | Lamps that are - in the traffic area of the audience - located at a height of 2 m above the floor must be secured with a protection against breaking due to mechanical stress. Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”) |
|
Motor vehicle washing rooms | IP54 | Weather-proof luminaires: Duroxo⋅⋅⋅ | Direct contact of the luminaire with cleaning agents can lead to embrittlement of diffuser fasteners, etc., cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature. |
|
Museums | IP20 | Based on photometric requirements | Lighting planning is very particular, mostly accent lighting. Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Music schools, concert halls | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Polaron IQ⋅⋅⋅ | Take noise level into consideration, luminaire louvres and loose components as well as ceiling components can be excited into resonance vibrations, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
|
|
|
|
|
Non-woven fabric and wadding processing | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
|
|
|
|
|
Offices | IP20 | Diffuser luminaires: Arimo Slim CDP⋅⋅⋅, Belviso Active⋅⋅⋅, louvre luminaires: Arimo Slim MRX⋅⋅⋅, Work zone luminaires, if applicable: Bicult⋅⋅⋅, Belviso S⋅⋅⋅, Offset S⋅⋅⋅, Lateralo⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅, Parelia⋅⋅⋅ | In case of VDU workspaces consider luminance limitation, light accents increase the perceived value of the lighting. |
|
Operating rooms, general lighting | IP20 | Cleanroom luminaires: Fidesca PM⋅⋅⋅, Fidesca SD⋅⋅⋅ |
For reasons of hygiene, IP54 and/or IP65 are recommended, when cleaning with aggressive cleaning agents, consider chemical resistance (see Chapter “Chemical safety” ), consider compatibility with IR control systems (e.g. OR table control, see Chapter “Compatibility with IR remote controls”) |
|
Outdoor storage areas for hay, straw (roofed over) | IP54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅, Duroxo⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. |
|
|
|
|
|
|
Paper processing facilities | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Pig-fattening farms | IP54 | Weather-proof luminaires: Duroxo⋅⋅⋅ |
Premises posing a fire hazard. consider ammonia resistance (see chapter “Chemical safety” ). |
|
Plastic fibre processing | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Platforms, not roofed over | IPx3 | Outdoor luminaires | Cleaning with jet water: IPx5, with pressure washers: IPx9, limit glare. |
|
Platforms, roofed over | IPx1 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, limit glare. |
|
Premises posing a fire hazard | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ |
|
|
Public areas | IP 20 |
Wall-mounted luminaires (z. B. 3331⋅⋅⋅, Deca⋅⋅⋅, Polaron IQ⋅⋅⋅, 74R⋅⋅⋅, 74Q⋅⋅⋅, Downlights: Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Inplana⋅⋅⋅, Onplana⋅⋅⋅, Accent luminaires | In case of VDU workspaces consider luminance limitation, light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Pump rooms | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
|
|
|
|
|
Reading halls | IP20 | Diffuser luminaires: Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Arimo Slim⋅⋅⋅, Free-standing luminaires: Belviso S⋅⋅⋅, Offset S⋅⋅⋅, Work zone luminaires: Bicult⋅⋅⋅, Lateralo⋅⋅⋅, Luceos Slim⋅⋅⋅, Parelia⋅⋅⋅ | Take noise level into consideration, avoid reflectice glare on reading areas and VDUs, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
|
|
|
|
|
Salesrooms (business premises) | IP20 | Downlights: Inplana⋅⋅⋅, Onplana⋅⋅⋅, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Diffuser luminaires: Arimo Slim MRX ⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Accent luminaires | In case dust occurs: IP50. In case of VDU workspaces consider luminance limitation, consider increased requirements of colour rendering, where applicable. Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Sanitary rooms | IP20 | Downlights, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Diffuser luminaires: Acuro⋅⋅⋅, Solvan Flow C⋅⋅⋅, Weather-proof luminaires | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Sawmills | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅, Aragon⋅⋅⋅, 713⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard, plan safety lighting for workspaces with particular hazards (also see chapter “Emergency lighting”). |
|
Schools | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Solvan Flow C⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅ |
Consider glare limitation. Plan for lighting for blackboard (also see Chapter “Lighting of educational facilities”). Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Schools, blackboard | IP 20 | Louvre and diffuser luminaires: 504⋅⋅⋅ | Utilise luminaires with asymmetrical or narrow-angle light distribution, consider glare limitation. |
|
Schools, special-subject classrooms | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Solvan Flow C⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅ | Consider glare limitation. Plan for lighting for blackboard and experiment table (also see Chapter “Lighting of educational facilities”), vorsehen. Emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Showers and bathrooms, general | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Acuro⋅⋅⋅, Solvan Flow C⋅⋅⋅, Polaron IQ⋅⋅⋅, Arimo Slim CDP⋅⋅⋅ | Outside zones 0, 1 und 2. |
|
Showers and bathrooms, zone 0 | IPx7 |
| Cleaning with pressure washers: IPx9. |
|
Showers and bathrooms, zone 1 | IPx4 | LED luminaires, protection class III | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Showers and bathrooms, zone 2 | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Special-subject classrooms | IP20 | Diffuser luminaires: 3331⋅⋅⋅, Solvan Flow C⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅ | Consider glare limitation. |
|
Sports and gymnasium halls | IP20 | Ball-proof luminaires: Actison⋅⋅⋅ |
Ball-impact-resistant luminaires (see Chapter “Mechanical safety”). In case of radiant ceiling heating system, further inquiry required. |
|
Squash courts | IP20 | Ball-proof recessed diffuser luminaires: Actison⋅⋅⋅ with PMMA cover |
Closed luminaires, ball-impact-resistant (see Chapter “Mechanical safety”). Consideration special luminaire placement. In case of radiant ceiling heating system, further inquiry required. |
|
Stables for large and small animals | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, others on request | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. Consider ammonia resistance (see chapter “Chemical safety” ). |
|
Stables, ancillary rooms | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. Consider ammonia resistance (see chapter “Chemical safety” ). |
|
Stables, breeding rooms | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, others on request | In case dust occurs: IP54. Where applicable, premises posing a fire hazard. Consider ammonia resistance (see chapter “Chemical safety” ). |
|
Staircases, corridors | IP20 | 3331⋅⋅⋅, Downlights, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Inplana⋅⋅⋅, Onplana⋅⋅⋅, Wall-mounted luminaires: 74R⋅⋅⋅, 74Q⋅⋅⋅, 748⋅⋅⋅, Deca⋅⋅⋅, Polaron IQ⋅⋅⋅ | Avoid glare and irritations at stairs through lighting, LED luminaires preferred (in particular in case of automatic switching systems with short operating duration) |
|
Storage rooms, general | IP 20 | Protection rating dependent on stored goods, in case dust occurs: IP50. In case of VDUs avoid reflex formation |
||
Storerooms for bed feathers | IP50 | Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for feed, fertilizer | IP44 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. Where applicable, adhere to explosion protection. |
|
Storerooms for grain | IP54 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for hay, straw, jute, flax | IP54 | Continuous-line luminaires: E-Line IP54⋅⋅⋅, Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for raffia products, reed, and reed products | IP50 | Continuous-line luminaires: E-Line IP54⋅⋅⋅, Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for rags | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for sugar beet pulp (pellets) | IP50 | Diffuser luminaires:3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Storerooms for wood chips | P50 | Diffuser luminaires: 3331⋅⋅⋅, Weather-proof luminaires:Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Swimming baths | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Swimming pool, Zone 0 | IPx8 |
| Take chemical resistance into consideration, Zone 0 specialty luminaires required. |
|
Swimming pool, Zone 1 | IPx4 | LED luminaires, protection class III | Cleaning with jet water IPx5, special luminaires required. Take chemical resistance into consideration in areas with an atmosphere containing chlorine (see chapter “Chemical safety” , luminaires on request). |
|
Swimming pools, general | IP20 | Wall-mounted luminaires: 3331⋅⋅⋅, Deca⋅⋅⋅, Polaron IQ⋅⋅⋅, 74R⋅⋅⋅, 74Q⋅⋅⋅, Downlights: Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Inplana⋅⋅⋅, Onplana⋅⋅⋅, Accent luminaires | Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, take chemical resistance into consideration in areas with an atmosphere containing chlorine (see chapter “Chemical safety” , luminaires on request). |
|
|
|
|
|
|
Tablets, blackboards | IP20 | Louvre and diffuser luminaires: 504⋅⋅⋅ | Utilise luminaires with asymmetrical or narrow-angle light distribution, consider glare limitation. |
|
Teller windows, banks | IP20 | Diffuser luminaires:Arimo Slim CDP⋅⋅⋅, Arimo Sky⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim MRX⋅⋅⋅, Work zone luminaires, if applicable : Belviso S⋅⋅⋅, Offset S⋅⋅⋅, Lateralo⋅⋅⋅, Luceos Slim⋅⋅⋅, Lunexo⋅⋅⋅, Parelia⋅⋅⋅, Bicult⋅⋅⋅ | In case of VDU workspaces consider luminance limitation. Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Tennis halls | IP20 | Ball-proof luminaires: Actison⋅⋅⋅ |
Ball-impact-resistant luminaires (see Chapter “Mechanical safety”). Consider special luminaire placement. In case of radiant ceiling heating system, further inquiry required. |
|
Tents, event tents | IP54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Hallenspiegelleuchten: Mirona Fit⋅⋅⋅ | Lamps that are - in the traffic area of the audience - located at a height of 2 m above the floor must be equipped with a protection against breaking due to mechanical stress |
|
Textile processing | IP50 | Diffuser luminaires | Premises posing a fire hazard. |
|
Theatre workshops | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Theatres | IP20 | Wall-mounted luminaires: 3331⋅⋅⋅, Deca⋅⋅⋅, Polaron IQ⋅⋅⋅, 74R⋅⋅⋅, 74Q⋅⋅⋅, Downlights: Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Inplana⋅⋅⋅, Onplana⋅⋅⋅, Accent luminaires | Light accents increase the perceived value of the lighting. Emergency lighting of escape routes for 3 hour length of operation, anti-panic lighting (also see Chapter “Emergency lighting”) |
|
Treatment and examination rooms for ECG/EEG, and EMG measurements | IP20 | Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅, Arimo Slim CDP ⋅⋅⋅, Arimo Sky⋅⋅⋅ | Illumination level and light colour differing dependent on the type of examination, where applicable dimmable luminaires, in case of VDU workspaces, consider luminance limitation. |
|
|
|
|
|
|
Underground parking garages, garages, large parking garages | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Underground railway stations | IPx1 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅ | Limit glare, cleaning with jet water: IPx5, with pressure washers: IPx9, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Upholstery | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
|
|
|
|
|
VDU workspaces | IP20 |
Work zone luminaires, if applicable (see Offices) | Consider luminance limitation. |
|
|
|
|
|
|
Warehouses | IP20 | Downlights, Inperla Ligra⋅⋅⋅, Athenik Ligra⋅⋅⋅, Accent luminaires, Diffuser and louvre luminaires: Arimo Slim MRX ⋅⋅⋅, Belviso C⋅⋅⋅, Belviso D⋅⋅⋅, Belviso Active⋅⋅⋅ | In case dust occurs: IP50. In case of VDU workspaces consider luminance limitation, consider increased requirements of colour rendering, where applicable. Light accents increase the perceived value of the lighting, possibly lighting with colour-changing dynamics, emergency lighting of escape routes for 3 hour length of operation (also see Chapter “Emergency lighting”). |
|
Washing facilities – automobile | IP54 | Weather-proof luminaires: Nextrema⋅⋅⋅, Duroxo⋅⋅⋅ | Direct contact of the luminaire with cleaning agents can lead to embrittlement of diffuser fasteners etc. (see chapter “Chemical safety” ), Cleaning with jet water: IPx5, with pressure washers: IPx9, consider ambient temperature. |
|
Weaving plant | IP50 | Diffuser luminaires: 3331⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. |
|
Wet workshops, e.g. stone working | IPx4 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Wine and beer cellars | IPx1 | Weather-proof luminaires: Duroxo⋅⋅⋅, Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Cleaning with jet water: IPx5, with pressure washers: IPx9. |
|
Wood flour processing | IP50 | 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard. Where applicable, adhere to explosion protection. |
|
Wood working | IP50 | 3331⋅⋅⋅, Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅, 748⋅⋅⋅, Continuous-line luminaires: E-Line IP54⋅⋅⋅ | Premises posing a fire hazard, plan safety lighting for workspaces with particular hazards (also see chapter “Emergency lighting”). |
|
Workshops – automobile | IP20 | Weather-proof luminaires: Nextrema⋅⋅⋅, Araxeon⋅⋅⋅, Aragon⋅⋅⋅, Oleveon Fit⋅⋅⋅ Continous-line luminaires: E-Line⋅⋅⋅, C-Line⋅⋅⋅, Coriflex⋅⋅⋅ | In case of cleaning with jet water: IPx5, with pressure washers: IPx9. Stand-by lighting must be planned for in case of workspaces with particular hazards (also see Chapter “Emergency lighting”). In case of contact with fats and oils, luminaire covers made of PMMA are recommended. |
|
- 1.
- HD 60364-5-559, Low-voltage electrical installations - Part 5-559: Selection and erection of electrical equipment - Luminaires and lighting installations
- 2.
- DIN VDE 0100-737, Erection of low-voltage installations - Humid and wet areas and locations, outdoor installations
- 3.
- HD 60364-4-42, Low voltage electrical installations - Part 4-42: Protection for safety - Protection against thermal effects
- 4.
- HD 60364-7-701, Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower
- 5.
- DIN VDE 0100-702, Low-voltage electrical installations - Part 7-702: Requirements for special installations or locations - Basins of swimming pools, other water basins and fountains
- 6.
- HD 60364-7-705, Low-voltage electrical installations - Part 7-705: Requirements for special installations or locations - Agricultural and horticultural premises
- 7.
- HD 60364-7-710, Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations
- 8.
- prHD 60364-7-711, Low voltage electrical installation - Part 7-711: Requirements for special installations or locations - Exhibitions, shows and stands
- 9.
- HD 60364-7-714, Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations
- 10.
- HD 60364-7-718, Low-voltage electrical installations - Part 7-718: Requirements for special installations or locations - Communal facilities and workplaces
- 11.
- prHD 60364-7-722, Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles
- 12.
- EN 50172, Emergency escape lighting systems
- 13.
- DIN 18032-3, Sport halls - Halls for gymnastics, games and multi-purpose use - Part 3: Testing of safety against ball throwing